Model | AdaptableMotor(KW) | Output current(A) | Size (mm) | |
Heavyload / Lightload | Heavyload | Lightload | (H x D x W) | |
Single phase: 2 00-240V,50/60Hz | ||||
KDE300A-R75GS2 | 0,75 KW | 4 | 7 | 186x125x164 |
KDE300A-1R5GS2 | 1,5 KW | 7 | 9,6 | 186x125x164 |
KDE300A-2R2GS2 | 2,2 KW | 9,6 | 17 | 186x125x164 |
Three phase: 380 -480V,50/60Hz | ||||
KDE300A-R75GT4 | 0,75 KW | 2,1 | 4 | 186x125x164 |
KDE300A-1R5GT4 | 1,5 KW | 3,8 | 5,6 | 186x125x164 |
KDE300A-2R2GT4 | 2,2 KW | 5,1 | 9 | 186x125x164 |
KDE300A-3R7G/5R5PT4 | 3,7 / 5,5 KW | 9 | 13 | 248x160x183 |
KDE300A-5R5G/7R5PT4 | 5,5 / 7,5 KW | 13 | 17 | 248x160x183 |
KDE300A-7R5G/011PT4 | 7,5 / 11 KW | 17 | 25 | 248x160x183 |
KDE300A-011G/015PT4 | 11 / 15 KW | 25 | 32 | 322x208x192 |
KDE300A-015G/018PT4 | 15 / 18,5 KW | 32 | 37 | 322x208x192 |
KDE300A-018G/022PT4 | 18,5 / 22 KW | 37 | 45 | 322x208x192 |
KDE300A-022G/030PT4 | 22 / 30 KW | 45 | 60 | 455x290x218 |
KDE300A-030G/037PT4 | 30 / 37 KW | 60 | 75 | 455x290x218 |
KDE300A-037G/045PT4 | 37 / 45 KW | 75 | 90 | 555x320x240 |
KDE300A-045G/055PT4 | 45 / 55 KW | 91 | 110 | 555x320x240 |
KDE300A-055G/075PT4 | 55 / 75 KW | 112 | 152 | 635x410x239 |
KDE300A-075G/090PT4 | 75 / 90 KW | 150 | 176 | 635x410x239 |
KDE300A-090G/110PT4 | 90 / 110 KW | 176 | 210 | 654x460x340 |
KDE300A-110G/132PT4 | 110 / 132 KW | 210 | 253 | 654x460x340 |
KDE300A-132G/160PT4 | 132 / 160 KW | 253 | 304 | 795x460x320 |
KDE300A-160G/200PT4 | 160 / 200 KW | 304 | 357 | 886x520x385 |
KDE300A-200G/220PT4 | 200 / 220 KW | 377 | 426 | 886x520x385 |
KDE300A-220G/250PT4 | 220 / 250 KW | 426 | 465 | 1350x750x432 |
KDE300A-250G/280PT4 | 250 / 280 KW | 465 | 520 | 1350x750x432 |
KDE300A-280G/315PT4 | 280 / 315 KW | 520 | 585 | 1350x750x432 |
KDE300A-315G/355PT4 | 315 / 355 KW | 585 | 650 | 1450x850x432 |
KDE300A-355G/400PT4 | 355 / 400 KW | 650 | 725 | 1450x850x432 |
KDE300A-400G/450PT4 | 400 / 450 KW | 725 | 820 | 1450x850x432 |
KDE300A-450G/500PT4 | 450 / 500 KW | 820 | 860 | 1450x850x432 |
KDE300A-500G/560PT4 | 500 / 560 KW | 860 | 950 | 1800x1050x460 |
KDE300A-560G/630PT4 | 560 / 630 KW | 950 | 1100 | 1800x1050x460 |
[windfall_header_address image_type="image" contact_image="https://kdegroup.com.vn/wp-content/uploads/2020/03/call.png" link_text="0903-228-933" link="tel:+84903228933"]
Products
KDE300A Inverter
Inuput Voltage | 1phase/3phase 220V:200V~240V 3 phase 380V-480V:380V~480V |
Allowed Voltage fluctuation range | -15%~10% |
Input frequency | 50Hz / 60Hz,fluctuation less than 5% |
Output Voltage | 3phase:0~input voltage |
Overload capacity | General purpose application:60S for 150% of the rated current Light load application:60S for 180% of the rated current |
Control mode | V/f control Sensorless flux vector controlwithout PG card(SVC) Sensor speed flux vector control with PG card (VC) |
Operating mode | Speed control, Torque control(SVC and VC) |
Speed range | 1:100 (V/f) 1:200( SVC) 1:1000 (VC) |
Speed control accuracy | ±0.5% (V/f) ±0.2% (SVC) ±0.02% (VC) |
Speed response | 5Hz(V/f) 20Hz(SVC) 50Hz(VC) |
frequency range | 0.00~600.00Hz(V/f) 0.00~200.00Hz(SVC) 0.00~400.00Hz(VC) |
Input frequency resolution | Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.1% |
Startup torque | 150%/0.5Hz(V/f) 150%/0.25Hz(SVC) 150%/0Hz(VC) |
Torque control accuracy | SVC:within 5Hz10%,above 5Hz5% VC:3.0% |
V/f curve | V / f curve type: straight line, multipoint, power function, V / f separation; Torque boost support: Automatic torque boost (factory setting), manual torque boost |
Frequency giving ramp | Support linear and S curve acceleration and deceleration; 4 groups of acceleration and deceleration time, setting range 0.00s ~ 60000s |
DC bus voltage control | VdcMax Control: Limit the amount of power generated by the motor by adjusting the output frequency to avoid over-voltage trip; VdcMin control: Control the power consumption of the motor by adjusting the output frequency, to avoid jump undervoltage fault |
Carrier frequency | 1kHz~12kHz(Varies depending on the type) |
Startup method | Direct start (can be superimposed DC brake); speed tracking start |
Stop method | Deceleration stop (can be superimposed DC braking); free to stop |
Be the first to review “KDE300A Inverter” Cancel reply
Reviews
There are no reviews yet.